TYPICAL PHYSICAL PROPERTIES OF PERLITE CONCRETE
(Pittsburgh Testing Laboratory and R.W. Hunt Company Engineers)

Oven Dry Density Dry Density Range Compressive Strength Range Minimum Compressive Strength Wet Density When Placed
lbs/ft3 kg/m3 lbs/ft3 kg/m3 lbs/in2 kPa lbs/in2 kPa lbs/ft3 kg/m3
36.0 576 34.0-40.0 544-640 350-500 2413-3447 350 2413 50.5 808.0
30.5 488 28.0-34.0 448-544 230-340 1585-2344 230 1585 45.5 728.0
27.0 432 24.0-28.0 384-448 140-200 965-1378 140 965 40.5 648.0
22.0 352 20.0-24.0 320-384 80-125 552-861 80 552 36.5 584.0

 

 

 

 

Information given herein is from sources considered reliable, but no guarantee of accuracy can be made or liability assumed.  Your supplier may be able to provide you with more precise data.  Certain compositions or processes involving perlite may be the subject of patents.